Showing 16–30 of 82 results

cooper cooper FXP2200CPD series
0 out of 5

• Flexible, high specification system
• Very easy to maintain and service
• Suitable for a large range of projects
• No fuses required
• Maintenance free poly switch circuit protection, with
auto reset
• Class change and programmable fire/fault relay as
standard on 2/4 zone and fire and fault on the 8 zone
• Discreet panel design
• Numerical access code (no lost keys)
• The 8 zone variant features configurable zonal relay
card option and interlink
• Supplied complete with battery for 24 hour standby

 

 Related Products:

  • Optical smoke beam detector for conventional fire systems
  • Remote indicator for conventional fire systems
  • Sounder detector base for conventional fire systems
  • Ultra-low current sounder for conventional fire systems
  • UL optical, photo thermal & heat conventional detector range
  • Sounder visual alarm device for conventional fire systems

cooper cooper Horn Strobe and Horn Notification Appliances
0 out of 5

The Wheelock® ExcederTM Series incorporates high reliability and
high efficiency optics to minimize current draw allowing for a greater
number of appliances on the notification appliance circuit. All strobe
models feature an industry first of 8 candela settings on a single
appliance. Models with an audible feature 3 sound settings (90, 95,
99 dB). All switches to change settings, can be set without the use
of a tool and are located behind the appliance to prevent tampering.
Wall models feature voltage test points to take readings with a
voltage meter for troubleshooting and AHJ inspection.

 

 Related Products:

  • Optical smoke beam detector for conventional fire systems
  • Remote indicator for conventional fire systems
  • Sounder detector base for conventional fire systems
  • Ultra-low current sounder for conventional fire systems
  • UL optical, photo thermal & heat conventional detector range
  • Sounder visual alarm device for conventional fire systems

cooper cooper Micro Single Channel Output Unit
0 out of 5

• Soft addressed
• Integral short circuit isolator
• Single address
• Non latching changeover
relay contacts
• Suitable for switching low
volts control gear
• Optional variant:

 

   Related Products:

  • Visual alarm device for conventional fire systems
  • Wheelock Exceder horn strobes
  • Wheelock Exceder horns
  • Xenon sounder beacon for conventional fire systems
  • Wheelock RSS strobes
  • Wheelock Exceder strobes

cooper cooper repeater cf3000PR
0 out of 5

• Fully passive
• Up to 200 Repeaters can be
connected to the loop
• Surface or semi-recessed
mounting
• 2 x 40 backlit LCD display and
6 supervisory LED’s
• Compact size

 

   Related Products:

  • ULFX6000
  • ULFX6000RM
  • ULMIU872
  • ULMCIM
  • ULMCIM-C
  • ULMCOM
  • ULMCOM-S

cooper cooper ULFX6000 & ULFX6000RM
0 out of 5

• Approvals include: UL Standard 1971, UL Standard 1480, New York
City (MEA), California State Fire Marshall (CSFM), Factory Mutual
(FM), and Chicago (BFP) See approvals by model in Specifications
and Ordering Information
• ADA/NFPA/UFC/ANSI compliant
• Meets OSHA 29 Part 1910.165
• Wall mount models are available with Field Selectable Candela
Settings of 15/30/75/110cd or 135/185cd (Multi-Candela models) or
1575cd (Single Candela model)
• Ceiling mount models are available with field selectable candela
settings of 15/30/75/95cd or 115/177cd (multi-candela models)
• Strobes produce 1 flash per second over the regulated voltage range
• 24 VDC with wide UL “Regulated Voltage” using filtered DC or
unfiltered VRMS input voltage
• Synchronize with sync modules or panels with built-in Wheelock
Patented Sync Protocol
• Field selectable taps for 25 or 70 VRMS operation from 1/8 watt
to 8 watts
• High efficiency design for maximum output at minimum wattage
across a frequency range of 400 to 4000 HZ
• Fast installation with IN/OUT screw terminals using #12 to #18
AWG wires

 

 Related Products:

  • Sounder detector base for conventional fire systems
  • Visual alarm device for conventional fire systems
  • UL optical, photo-thermal & heat addressable detector range
  • UL optical, photo thermal & heat conventional detector range
  • Wheelock Exceder horns

cooper cooper ULMCIM
0 out of 5

• Soft addressed
• Integral short circuit isolator
• Single address
• Suitable for monitoring:
– Flow switches
– Non fire inputs
– Auxillary panels
• Optional variant:
– ULMCIM-C

 

Related Products:

  • Compact wall sounder for conventional fire systems
  • Loop splitter for addressable fire alarm systems
  • Loop mimic PCB for addressable fire systems
  • Loop design calculator software for fire systems
  • Loop tester kit for addressable fire systems

Fire alarm Crowcon Fgard IR3 flame detector
0 out of 5

The Fgard IR3 delivers superior performance in the detection of hydrocarbon fires, using the latest infrared (IR) flame detection algorithms to minimise the risk of false alarms.
The Fgard IR3 has been independently tested to demonstrate it can detect a hydrocarbon fuel pan fire at nearly 200 feet in less than 5 seconds, maximising the time you have to respond in an emergency.
Its multi-spectrum IR will detect all hydrocarbon fires with intelligent heated optics, meaning no condensation, ice or water affecting detection. Plus, its advanced optical verification checks cleanliness of the lens and electronic circuitry, meaning no reflector optical check is needed, and a large optical surface results in far fewer false alarms.
Applications
Typical applications include:
� On / Offshore Oil and Gas
Processing Facilities
� Refineries
� Petrochemical Plants
� Chemical Facilities
� Pharmaceutical
� Aircraft Hangars
� Road Tunnels
� Power Generation
� Tank Farms
� Road & Rail Loading Racks
� LNG / LPG
� Warehouses / Storage Areas
� Waste Recycling / Biomass Plants
� Printing Industry
Features and benefits
� Multi Spectrum IR design delivers long detection
distances and enhanced false alarm immunity
� Continuous optical test, without a reflector
•Verifies operation and improves device up-time
� Microprocessor controlled heated optics
•Maintains operation in harsh weather
conditions (snow, ice, condensation)
� International hazardous area approvals
•FM / ATEX / IEC Ex / INMETRO / PESO
� Certified performance testing to multiple fuels
•FM 3260
•EN 54-10
� Adjustable sensitivity levels
•For application flexibility
•Ensure detectors do not cross vote
� External testing with a long-range flame simulator
•Minimises the need for scaffolding
� Easy integration using industry
standard outputs:
•Alarm and Fault Relays
•4-20mA
•HART®, as standard
� Certified SIL 2 Capable
•5-year warranty

cooper eaton D200-HO
0 out of 5

The D200-HO and DET detector range offers a multi purpose conventional photoelectric smoke heat and conventional heat detector suitable for applications within 2-wire conventional systems and addressable systems suitable for conventional detectors.

cooper eaton Efxn 533
0 out of 5

JSB Optical Smoke Detector
A comprehensive range of conventional detectors are available for the JSB EFX2200 range of fire detection panels.
Features:
* LPCB 3rd party approved
* Low profile design
* 360° viewable LED design
* Removable detector chamber for cleaning
* Common mounting base
* New enhanced detectors feature Drift compensation and Chamber monitoring (FXN533 & FXN632)

cooper eaton FX 6100/FX61002
0 out of 5

The FX 6100/FX61002 range is available as a high specification 1 or 2 loop intelligent addressable control panel, offering sophisticated functionality with simple end user operation.
FX6100 uses soft addressing to minimise installation time and remove the potential for error associated with manual addressing.
Features and Benefits
.Available in 1 and 2 loop versions
.Up to 200 addresses per loop
.Full network capability up to 126 panels
.Soft addressing
.Large versatile touch-screen user interface
.Multi-language selection capability
. Integral battery and power supply
.Flexible cause and effect programming
.Simple to operate end user touch-screen interface​

cooper eaton FX6000PR
0 out of 5

The FX6000PR is a cost effective passive repeater panel
which can be programmed via its informative display to
be either fully passive (display only) or semi passive
(restricted system control).
When loop connected the repeater panel will display the
system information text of the connected control panel
and will provide a fire indication, with panel number,
of any connected network control panel that has fire
activation.

cooper eaton FXN501
0 out of 5

Eaton FXN501 Addressable Surface Callpoint is compatible with the Eaton: JSB range of intelligent addressable fire systems. These intelligent addressable call points are attractively designed, simple to install, and are supplied as standard with a frangible glass element and a test key for ease of maintenance

cooper eaton Sg 42bk1
0 out of 5

Sg 42bk1 double action call point
• Complete with Initiating module (addressable variants only)
• Key reset
• Corrosion resistant gold plated SPST contacts
• High-gloss red enamel finish with raised white lettering
• Class A, style 7 SLC
• Quick and simple to install
• High quality die cast metal case for lasting performance
• No hard addressing required with initiating unit (ULMCIM-C – plug and play)
• Easy to maintain/service

cooper eaton Uchr-2w
0 out of 5

Uchr-2w
Eaton UL Conventional detector range,
Conventional, Heat, UL Systems, White
Plastic, Multi-Mode

cooper eaton ULFX330
0 out of 5

Heat sensor (ULFX330)
Rate of rise with fixed heat sensor settings will detect
a rapid increase in temperature or temperatures above
135°F, and should be used in environments where the
ambient conditions might cause false alarms if smoke
detection were to be used, for example where there
is a high level of dust, fumes, steam or smoke under
normal conditions.