Showing 1–15 of 82 results
58000-300 CO DETECTOR
XP95, Discovery and
CoreProtocol® compatible
The Discovery Carbon Monoxide (CO) Detector is an analogue
addressable fire detector that has the features that follow:
•
Early warning of carbon based smouldering fires
•
Resistance to false alarms in areas with high levels of
steam and other airborne particles
•
Ideal for protecting small volume sleeping risk areas
•
Resistance to contamination in dirty and dusty
conditions
•
Excellent supplement to fire detection systems to
improve detection of smouldering hydrocarbon fires
AUTO-DIALER 911 Microchip Automatic Alarm Instrument, CCTV�Security Alarm Automatic System�RecordingDuration:20 seconds, telephone numbers and audio�information�Remain intact even ifthe power is off, 4 groups of telephones and�each group is able to save as long as 16 digits.
This electronic sounder is designed for use
with fire alarm systems, security systems
and industrial signaling systems. Combined
sounder and beacon provides an audio-visual
warning which is suitable for places where
high sound output and visual indication is
required.
Characteristics
• 32 signal tones selectable by Dip switch.
• High sound output with low current consumption.
• Volume Control as standard.
• Two sets of IN and OUT terminals, easy for installation.
Discovery UL Open-Area Sounder Visual Indicator with red body and red flash.
UL 464 Certified
15 Pairs of Tones (EN54-3 Sounder)
7 Volume Levels
Visual Indicator Beacon (Red-Flash)
Discovery (works on XP95 & CoreProtocol)
Elite RS is a versatile range of UL/FM approved open protocol fire alarm
control panels.
Available with one or two detection loops capable of hosting Hochiki or
Apollo UL devices. Elite RS uses microprocessor-based electronics to provide
a flexible control system with high reliability and integrity.
Suitable for all small to medium sized fire detection systems, Elite RS control
panels can be expanded and networked to become part of significantly larger
systems if the need arises, therefore providing a future-proof solution for any
installation.
With its large graphical display and ergonomic button and indicator layout,
the Elite RS control pabel is simple and straightforward to understand for
installers, commissioning engineers and end users alike.
The XP95A Heat Detector monitors temperature by using a single thermistor which provides a count output proportional to the external air temperature, reporting an alarm at 135°F.
Reliable fire detection in areas with a wide temperature range from 32°F to 151°F
Ideal for environments that are dirty or smoky under normal circumstances
Unaffected by wind and atmospheric pressure
Alarm flag for fast alarm responding
The Discovery UL Manual Pull Station is used to manually initiate an alarm signal on the fire detection system.
UL38 Certified
Reports an alarm in under 0.2 seconds
Key lock
Easily resettable
Suitable for semi flush or surface mounting
XP95, (Discovery and CoreProtocol compatible)
The XP95A Photoelectric Smoke Detector uses the light scatter principle to quickly and effectively detect a range of slow burning and smouldering fires.
Reliable fire detection in areas with a wide temperature range from 32°F to 100°F
Ideal for escape routes
Unaffected by wind and atmospheric pressure
Insect resistant screen
• Listed to UL standard 2075
• 4 wire, system monitored
• Local sounder
• Low current draw
• Alarm relay, Form C
• Trouble relay, Form A
• Dual LED’s
• Test/Hush button
• SEMS wiring terminals
• Mount to single gang electrical box or surface mount to wall
or ceiling
• Optional drywall anchors included
Consilium fds 303 IR3 flame detector 🔥🔥
High performance hydrogen flame detection.
The FDS303 complements the CD-F-301 and
CD-F-300 Visual Flame Detectors by delivering
superior performance in the detection of
hydrocarbon fires which are not detectable in the
visible spectrum. The FDS303 utilizes the latest IR
flame detection algorithms to ensure maximum
false alarm immunity.
Applications
Typical applications include:
• On/Offshore Oil and Gas processing facilities
• Refineries
• Petrochemical plants
• Chemical facilities
• Chemical facilities
• Pharmaceutical
• Pharmaceutical
• Aircraft hangars
• Road tunnels
• Road tunnels
• Power generation
• Tank farms
• Tank farms
• Road and rail loading racks
• LNG / LPG
• LNG / LPG
• Warehouses/storage areas
• Waste recycling/b
Features and Benefits
• Multi spectrum IR design delivers long
detection distances and enhanced false alarm
immunity
• Continuous optical test, without a reflector
ο Verifies operation and improves device
up-time
1 Fixed Zone
• Supports up to 32 detectors
• Unlimited call points
• 1 “fire” and 1 “fault” relay outputs
• 1 monitored sounder outputs
• Active EOL allowing continuous monitoring of inputs
• Walk test
• LED indication
• Levels of access protected by means of security key
• Plastic box
eatures
• 4 Fixed Zones
• Supports up to 128 detectors
• Unlimited call points
• 1 “fire” and 1 “fault” relay outputs
• 2 monitored sounder outputs
• Active EOL allowing continuous monitoring of inputs
• Walk test
• LED indication
• Levels of access protected by means of security key
• Plastic box
• Audio and visual alerts
• Floor plan system visualisation
• 3D idle/overview mode including mouse hover/click interaction
• Sweeping animations
• Programmable buttons and displays
• Quick and intuitive to set up and use
• Remote and multi-user access with defined credentials
• Password and pin code protection
• Network history view/search
• Printable reports
• Multi network supervision over TCP/IP
