Showing 16–24 of 24 results

cooper FX6000PR
0 out of 5

The FX6000PR is a cost effective passive repeater panel
which can be programmed via its informative display to
be either fully passive (display only) or semi passive
(restricted system control).
When loop connected the repeater panel will display the
system information text of the connected control panel
and will provide a fire indication, with panel number,
of any connected network control panel that has fire
activation.

cooper FXN501
0 out of 5

Eaton FXN501 Addressable Surface Callpoint is compatible with the Eaton: JSB range of intelligent addressable fire systems. These intelligent addressable call points are attractively designed, simple to install, and are supplied as standard with a frangible glass element and a test key for ease of maintenance

cooper MBG914 / FX201
0 out of 5

Cooper CX201 Conventional Call Point (MBG914 / FX201)
All Cooper conventional call points have integral short circuit isolators and have a status LED fitted as standard. To simplify replacement of glass element call points are fitted with fast fit clip on front covers.
Benefits and Features:
* Approved to EN54 -11
* Convenient clip fixed front cover
* One key for test and cover removal
* Available as weather proofed

cooper Sg 42bk1
0 out of 5

Sg 42bk1 double action call point
• Complete with Initiating module (addressable variants only)
• Key reset
• Corrosion resistant gold plated SPST contacts
• High-gloss red enamel finish with raised white lettering
• Class A, style 7 SLC
• Quick and simple to install
• High quality die cast metal case for lasting performance
• No hard addressing required with initiating unit (ULMCIM-C – plug and play)
• Easy to maintain/service

cooper Uchr-2w
0 out of 5

Uchr-2w
Eaton UL Conventional detector range,
Conventional, Heat, UL Systems, White
Plastic, Multi-Mode

cooper ULCF3000 range
0 out of 5

• Large versatile touch-screen user interface
• 2 or 4 Class A Style 7 SLC loops
• Event history buffer (9,999 events) with date/time
stamp
• 4 Notification appliance circuit (NAC’s) outputs
• Dedicated alarm, trouble, AC trouble relays
• Integral short circuit isolators
• Up to 200 addresses per loop
• Full network capability up to 126 panels
• Supports a comprehensive range of soft addressing
modules and devices for greater flexibility in design
• Menu driven graphical user interface for ease of
operation
• Reduced commissioning time through soft
addressing and auto learn functions
• Programming and trouble shooting time minimised
by using a range of features such as auto config,
walk test, system details menus

 

cooper ULFX320
0 out of 5

ULFX320 range has multiple options for intelligent addressable sensors. All sensors are designed for optimum functionality in mid-large sized builds. They are all soft addressed and have integral short circuit isolators.

cooper ULFX330
0 out of 5

Heat sensor (ULFX330)
Rate of rise with fixed heat sensor settings will detect
a rapid increase in temperature or temperatures above
135°F, and should be used in environments where the
ambient conditions might cause false alarms if smoke
detection were to be used, for example where there
is a high level of dust, fumes, steam or smoke under
normal conditions.

cooper ulmcim-c
0 out of 5

An extensive range of interfaces are available to
support the Eaton range of UL intelligent addressable
control panels, providing solutions for most design
requirements.
The UL single channel output unit (ULMCOM) is an
extremely compact unit ideal for incorporation in to
external equipment and suitable for switching low
voltages (24V dc at 1A maximum).
This unit incorporates a set of non latching relay contacts
and is suitable for switching HVAC control circuits, plant
shutdown control circuits, fire door closure etc.
The ULMCOM is identified by the panel as an input /
output unit, with a maximum of 20 units permitted per
loop.