Showing 1–15 of 32 results

apollo 58000-300 CO DETECTOR
0 out of 5

58000-300 CO DETECTOR
XP95, Discovery and
CoreProtocol® compatible
The Discovery Carbon Monoxide (CO) Detector is an analogue
addressable fire detector that has the features that follow:

Early warning of carbon based smouldering fires

Resistance to false alarms in areas with high levels of
steam and other airborne particles

Ideal for protecting small volume sleeping risk areas

Resistance to contamination in dirty and dusty
conditions

Excellent supplement to fire detection systems to
improve detection of smouldering hydrocarbon fires

Fire alarm 911 auto dialer
0 out of 5

AUTO-DIALER 911 Microchip Automatic Alarm Instrument, CCTV�Security Alarm Automatic System�RecordingDuration:20 seconds, telephone numbers and audio�information�Remain intact even ifthe power is off, 4 groups of telephones and�each group is able to save as long as 16 digits.

Fire alarm AH03217
0 out of 5

This electronic sounder is designed for use
with fire alarm systems, security systems
and industrial signaling systems. Combined
sounder and beacon provides an audio-visual
warning which is suitable for places where
high sound output and visual indication is
required.
Characteristics
• 32 signal tones selectable by Dip switch.
• High sound output with low current consumption.
• Volume Control as standard.
• Two sets of IN and OUT terminals, easy for installation.

Fire alarm CO1224
5.00 out of 5

• Listed to UL standard 2075
• 4 wire, system monitored
• Local sounder
• Low current draw
• Alarm relay, Form C
• Trouble relay, Form A
• Dual LED’s
• Test/Hush button
• SEMS wiring terminals
• Mount to single gang electrical box or surface mount to wall
or ceiling
• Optional drywall anchors included

Fire alarm Consilium fds 303 IR3 flame detector
0 out of 5

Consilium fds 303 IR3 flame detector 🔥🔥
High performance hydrogen flame detection.
The FDS303 complements the CD-F-301 and
CD-F-300 Visual Flame Detectors by delivering
superior performance in the detection of
hydrocarbon fires which are not detectable in the
visible spectrum. The FDS303 utilizes the latest IR
flame detection algorithms to ensure maximum
false alarm immunity.
Applications
Typical applications include:
• On/Offshore Oil and Gas processing facilities
• Refineries
• Petrochemical plants
• Chemical facilities
• Chemical facilities
• Pharmaceutical
• Pharmaceutical
• Aircraft hangars
• Road tunnels
• Road tunnels
• Power generation
• Tank farms
• Tank farms
• Road and rail loading racks
• LNG / LPG
• LNG / LPG
• Warehouses/storage areas
• Waste recycling/b
Features and Benefits
• Multi spectrum IR design delivers long
detection distances and enhanced false alarm
immunity
• Continuous optical test, without a reflector
ο Verifies operation and improves device
up-time

Fire alarm Crowcon Fgard IR3 flame detector
0 out of 5

The Fgard IR3 delivers superior performance in the detection of hydrocarbon fires, using the latest infrared (IR) flame detection algorithms to minimise the risk of false alarms.
The Fgard IR3 has been independently tested to demonstrate it can detect a hydrocarbon fuel pan fire at nearly 200 feet in less than 5 seconds, maximising the time you have to respond in an emergency.
Its multi-spectrum IR will detect all hydrocarbon fires with intelligent heated optics, meaning no condensation, ice or water affecting detection. Plus, its advanced optical verification checks cleanliness of the lens and electronic circuitry, meaning no reflector optical check is needed, and a large optical surface results in far fewer false alarms.
Applications
Typical applications include:
� On / Offshore Oil and Gas
Processing Facilities
� Refineries
� Petrochemical Plants
� Chemical Facilities
� Pharmaceutical
� Aircraft Hangars
� Road Tunnels
� Power Generation
� Tank Farms
� Road & Rail Loading Racks
� LNG / LPG
� Warehouses / Storage Areas
� Waste Recycling / Biomass Plants
� Printing Industry
Features and benefits
� Multi Spectrum IR design delivers long detection
distances and enhanced false alarm immunity
� Continuous optical test, without a reflector
•Verifies operation and improves device up-time
� Microprocessor controlled heated optics
•Maintains operation in harsh weather
conditions (snow, ice, condensation)
� International hazardous area approvals
•FM / ATEX / IEC Ex / INMETRO / PESO
� Certified performance testing to multiple fuels
•FM 3260
•EN 54-10
� Adjustable sensitivity levels
•For application flexibility
•Ensure detectors do not cross vote
� External testing with a long-range flame simulator
•Minimises the need for scaffolding
� Easy integration using industry
standard outputs:
•Alarm and Fault Relays
•4-20mA
•HART®, as standard
� Certified SIL 2 Capable
•5-year warranty

Fire alarm Esser detector IQ8Quad 802382
0 out of 5

  • The reliable sensor principle for consistent

response performance at the highest level of

security against false alarms

  • Loop powered – no need for external power supply
    • Individual control of the sounder
    • Tones can be used for other purposes in addition to
    warning of fire, making the device ideal for use in
    schools (school bell) etc.
    • Soft start option, ideal for hospitals and nursing homes
    • No additional short address
    • Automatic synchronization of various IQ8Quad alarm signaling devices
    • Maximum sound level: 92 dB (A) at 1 m
    • Maximum sound pressure can be set
    • Multiple signal components can be combined to one signal template
    • Signal template and repetition rates can be set
    • Up to 26 different languages are available
    • 20 different signal tones, incl. DIN-tone
    • Low power consumption

Fire alarm FSL 100-IR3 honeywell flame detector
0 out of 5

The Honeywell FSL100 Series Flame Detectors are Optoelectronic flame detectors for a wide range of Light Industrial fire detection from Honeywell Analytics.

Honeywell’s FSL100 range of Light Industrial/Commercial Flame Detectors enables simple coverage of fire hazard areas across many fire hazard applications. Installation, set-up and operation are simple. Wide solid area coverage and fast speed of response optimise safety. With inbuilt automatic test and test lamps available to cover all models, reliability is ensured.

A range of middle-market Optical Flame Detectors join the HA FSX High-End products. Addresses a wide range of fire protection applications both indoors and outdoors. With 3 versions to cover a wide range of flaming fires: Ultraviolet (UV), Ultraviolet/Infrared (UV/IR) and Triple Infrared (IR3).

Detecting a wide range of Hydrocarbon and Non-Hydrocarbon flaming fires means that many application areas can be addressed. Wide viewing angleOptical detection of radiant energy in a solid angle Field of View enables coverage of a large risk area. A simple optional mounting bracket allows the FSL100 to be installed and aligned covering the hazard. Fast responseFar faster than other technologies, by responding to flaming fires in seconds enabling a more rapid response to danger before the fire can escalate.

FM Class 1, 2 & 3 Div2 can be installed indoors or outdoors and in Hazardous areas typically looking into a Div 1 area from a distance. FM 3260 performance certified to FM 3260 for flame Detector performance. Relay and current output (Fault and Alarm) Analog stepped output and Alarm/Fault relays for simple connectivity. Inbuilt Automatic Test and Simple to use Test LampsFSL100 maintains continuous internal health monitoring. Test lamps enable simple operational and field-of-view testing.

Fire alarm Gent Beam detector S4-34740
0 out of 5

Gent S4-34740 Beam Sensor Pair (Transmitter and Receiver) Excluding Bracket and Base

Gent S4-34740 S-Quad Addressable Loop Powered Beam Sensor Pair provides an enhanced solution for linear beam detection for applications where Gent S4 Vigilon point detection is either not practical or economic.

Powered and controlled via the loop, the beam is a market leading device with features such as one man alignment and commissioning which is achieved using the auto gain setting, this ensure the optimum alignment is reached.

Maintenance of the beam is enhanced with a key operated test feature which simulates the obscuration of the beam in a fire.

The Gent loop powered beam is certified to EN54 parts 12 and 17. Compatible with the full range of Vigilon and Nano control panels the S-Quad beam uses the panel software to ensure a fast response to fire while offering software filters to reduce the number of unwanted alarms.

Fire alarm Gent COMPACT-NC Compac
0 out of 5

The COMPACT-NC is a Compact Network Card for Vigilon Compact Control Panels.
This copper network card is used to allow data to pass between control panels in a Vigilon Compact networked fire system. The card must be plugged into the Master Control board MCB of the panel in a dedicated slot ‘CARD 2’. The card has terminals to accept external network wiring. A bank of dual-in-line switches on the card allow setting of address number and baud rate.
Key Features
* Links together 2 or more Vigilon Compact or Vigilon Compact Plus fire alarm panels.
* Expands the Vigilon compact panel

Fire alarm Gent COMPACT-PLUS
0 out of 5

Gent COMPACT-PLUS Vigilon Compact Plus 1-2 Loop Control Panel with 1 Loop Card
Vigilon Plus Control Panels are available in 3 sizes managing 2, 4 or 6 loops each accommodating up to 200 devices including advanced fire sensors, interfaces, call points, alarm sounders and visual alarms. The Compact Plus 2 loop panels and Vigilon Plus 4 loop panels are available with integrated 24 hour standby and the 6-loop panel has full 72 hr standby capacity

Fire alarm Gent Gent S4-710
0 out of 5

The S4-710 is specifically designed to be used with the Gent Vigilon range of Analogue Addressable Control Panels. This detector is an Optical Type Analogue Addressable Smoke Detector combined with a Heat Detection Element. It requires a Gent S4-700 base for mounting.
The S4-710 is a truly intelligent analogue sensor combining local processing in the sensor and the panel to achieve an immediate response to real fires whilst minimising the risk of false alarms.

Fire alarm Gent S3-S-R S3
0 out of 5

Gent S3-S-R S3 Sounder with Red Body
* S-Cubed offers a comprehensive range of loop powered alarm sounders with integrated voice and EN54-23 certified visual alarms. Combined with flexible configuration from the Gent by Honeywell fire control panels, this loop powered device can give a differentiated combination of audible and visual alarms for alert and general evacuation.

Fire alarm Gent S3-s-VAD-HPR-R
0 out of 5

The Gent S-Cubed offers a comprehensive range of loop powered alarm sounders with integrated voice and visual alarms. The sounders shall be capable of providing 3 different sound signals, which are selected/configured via the main control panel. Configuration of sounder patterns will not be carried out locally at individual sounders. In order to meet with the requirements of BS5839 Part 1, the frequency of sound signals emitted will be as follows:
Features & Benefits:
* 200 per loop
* Red & White options
* 103dbA at 1 metre
* 3 Sound signals
* 2 integral Line Isolators

Fire alarm Gent S4-34845
0 out of 5

S4-34845 Manual Call Point with Protective Cover & Resettable Element
The S4-34845 is a Addressable Manual Call Point (MCP) from the Gent range. The S4-34845 has an response time of less than 1 second. The S4-34845 Manual Call Point comes with a protective cover and also comes with the resettable element, which can be done at any given time using a Call Point Test Key seen in the related products.
The Addressable Range of Gent Manual Call Points (MCP) are for the Vigilon and Nano System, which are easy to install and have the ability to be mounted on standard installation back boxes or they can be mounted on bespoke red back boxes for surface mounting.