Showing 16–30 of 82 results

cooper cooper FX004R / FX000WP
0 out of 5

> High output sounder beacon
> Sounder and beacon with a single installation point
> Unobtrusive low profile design
> Volume contol
> Lockable base

cooper cooper FXP2200CPD series
0 out of 5

• Flexible, high specification system
• Very easy to maintain and service
• Suitable for a large range of projects
• No fuses required
• Maintenance free poly switch circuit protection, with
auto reset
• Class change and programmable fire/fault relay as
standard on 2/4 zone and fire and fault on the 8 zone
• Discreet panel design
• Numerical access code (no lost keys)
• The 8 zone variant features configurable zonal relay
card option and interlink
• Supplied complete with battery for 24 hour standby

 

 Related Products:

  • Optical smoke beam detector for conventional fire systems
  • Remote indicator for conventional fire systems
  • Sounder detector base for conventional fire systems
  • Ultra-low current sounder for conventional fire systems
  • UL optical, photo thermal & heat conventional detector range
  • Sounder visual alarm device for conventional fire systems

cooper cooper Horn Strobe and Horn Notification Appliances
0 out of 5

The Wheelock® ExcederTM Series incorporates high reliability and
high efficiency optics to minimize current draw allowing for a greater
number of appliances on the notification appliance circuit. All strobe
models feature an industry first of 8 candela settings on a single
appliance. Models with an audible feature 3 sound settings (90, 95,
99 dB). All switches to change settings, can be set without the use
of a tool and are located behind the appliance to prevent tampering.
Wall models feature voltage test points to take readings with a
voltage meter for troubleshooting and AHJ inspection.

 

 Related Products:

  • Optical smoke beam detector for conventional fire systems
  • Remote indicator for conventional fire systems
  • Sounder detector base for conventional fire systems
  • Ultra-low current sounder for conventional fire systems
  • UL optical, photo thermal & heat conventional detector range
  • Sounder visual alarm device for conventional fire systems

cooper cooper Micro Single Channel Output Unit
0 out of 5

• Soft addressed
• Integral short circuit isolator
• Single address
• Non latching changeover
relay contacts
• Suitable for switching low
volts control gear
• Optional variant:

 

   Related Products:

  • Visual alarm device for conventional fire systems
  • Wheelock Exceder horn strobes
  • Wheelock Exceder horns
  • Xenon sounder beacon for conventional fire systems
  • Wheelock RSS strobes
  • Wheelock Exceder strobes

cooper cooper repeater cf3000PR
0 out of 5

• Fully passive
• Up to 200 Repeaters can be
connected to the loop
• Surface or semi-recessed
mounting
• 2 x 40 backlit LCD display and
6 supervisory LED’s
• Compact size

 

   Related Products:

  • ULFX6000
  • ULFX6000RM
  • ULMIU872
  • ULMCIM
  • ULMCIM-C
  • ULMCOM
  • ULMCOM-S

cooper cooper ULFX6000 & ULFX6000RM
0 out of 5

• Approvals include: UL Standard 1971, UL Standard 1480, New York
City (MEA), California State Fire Marshall (CSFM), Factory Mutual
(FM), and Chicago (BFP) See approvals by model in Specifications
and Ordering Information
• ADA/NFPA/UFC/ANSI compliant
• Meets OSHA 29 Part 1910.165
• Wall mount models are available with Field Selectable Candela
Settings of 15/30/75/110cd or 135/185cd (Multi-Candela models) or
1575cd (Single Candela model)
• Ceiling mount models are available with field selectable candela
settings of 15/30/75/95cd or 115/177cd (multi-candela models)
• Strobes produce 1 flash per second over the regulated voltage range
• 24 VDC with wide UL “Regulated Voltage” using filtered DC or
unfiltered VRMS input voltage
• Synchronize with sync modules or panels with built-in Wheelock
Patented Sync Protocol
• Field selectable taps for 25 or 70 VRMS operation from 1/8 watt
to 8 watts
• High efficiency design for maximum output at minimum wattage
across a frequency range of 400 to 4000 HZ
• Fast installation with IN/OUT screw terminals using #12 to #18
AWG wires

 

 Related Products:

  • Sounder detector base for conventional fire systems
  • Visual alarm device for conventional fire systems
  • UL optical, photo-thermal & heat addressable detector range
  • UL optical, photo thermal & heat conventional detector range
  • Wheelock Exceder horns

cooper cooper ULMCIM
0 out of 5

• Soft addressed
• Integral short circuit isolator
• Single address
• Suitable for monitoring:
– Flow switches
– Non fire inputs
– Auxillary panels
• Optional variant:
– ULMCIM-C

 

Related Products:

  • Compact wall sounder for conventional fire systems
  • Loop splitter for addressable fire alarm systems
  • Loop mimic PCB for addressable fire systems
  • Loop design calculator software for fire systems
  • Loop tester kit for addressable fire systems

Fire alarm Crowcon Fgard IR3 flame detector
0 out of 5

The Fgard IR3 delivers superior performance in the detection of hydrocarbon fires, using the latest infrared (IR) flame detection algorithms to minimise the risk of false alarms.
The Fgard IR3 has been independently tested to demonstrate it can detect a hydrocarbon fuel pan fire at nearly 200 feet in less than 5 seconds, maximising the time you have to respond in an emergency.
Its multi-spectrum IR will detect all hydrocarbon fires with intelligent heated optics, meaning no condensation, ice or water affecting detection. Plus, its advanced optical verification checks cleanliness of the lens and electronic circuitry, meaning no reflector optical check is needed, and a large optical surface results in far fewer false alarms.
Applications
Typical applications include:
� On / Offshore Oil and Gas
Processing Facilities
� Refineries
� Petrochemical Plants
� Chemical Facilities
� Pharmaceutical
� Aircraft Hangars
� Road Tunnels
� Power Generation
� Tank Farms
� Road & Rail Loading Racks
� LNG / LPG
� Warehouses / Storage Areas
� Waste Recycling / Biomass Plants
� Printing Industry
Features and benefits
� Multi Spectrum IR design delivers long detection
distances and enhanced false alarm immunity
� Continuous optical test, without a reflector
•Verifies operation and improves device up-time
� Microprocessor controlled heated optics
•Maintains operation in harsh weather
conditions (snow, ice, condensation)
� International hazardous area approvals
•FM / ATEX / IEC Ex / INMETRO / PESO
� Certified performance testing to multiple fuels
•FM 3260
•EN 54-10
� Adjustable sensitivity levels
•For application flexibility
•Ensure detectors do not cross vote
� External testing with a long-range flame simulator
•Minimises the need for scaffolding
� Easy integration using industry
standard outputs:
•Alarm and Fault Relays
•4-20mA
•HART®, as standard
� Certified SIL 2 Capable
•5-year warranty

cooper D200-HO
0 out of 5

The D200-HO and DET detector range offers a multi purpose conventional photoelectric smoke heat and conventional heat detector suitable for applications within 2-wire conventional systems and addressable systems suitable for conventional detectors.

edwards edwards est4
0 out of 5

• Investment-forward Platform Designed for the Future
Protects the past with backwards compatibility
for EST3 retrofits, flexible feature set.
• On-board Webserver
Remote device-independent access to system status reports.
• Built-in E-mail and E-mail-to-SMS Messaging
Instant notification of specific event types
sent to appropriate personnel.
• Large Full-color LCD Touch Screen with Tactile Buttons
Fast, intuitive access to service and responder functions.
• Five-color LED Indicators
System status at a glance, select the color needed
during programming, reduces replacement part
inventory, maximizes use of available infrastructure.
• Network data, audio data, and telephone
data share a single twisted pair or single fiber strand
Up to 75 percent less cabling, substantial
cost savings in material and labor.
• Backwards Compatibility with EST3
Wiring, devices, and most local rail modules are
backward compatible, providing easy migration
paths, economical transition to new technology.
• Existing Systems Supporting only
Network Data can also Support Voice Audio
Upgrades add value and extend capabilities in retrofit situations.

 

  Related Products:

  • EST3                                                                               EST3X
  • iO SERIES                                                                     Amplifiers
  • Annunciators (R-Series)                                            Batteries and Power Supplies
  • Pull Stations                                                                 Beam & Duct Detectors
  • SCALABLE ASPIRATING DETECTION                ModuLaser® Aspirating Smoke Detection System
  • VESDA by Xtralis®                                                    ModuLaser® Aspirating Smoke Detection
  • ModuLaser® Aspirating Detection                        CONFIGURATION IS KEY
  • Genesis LED Series                                                    Genesis Outdoor Series
  • Universal Room-Side Wiring Plate                        G4SE Strobe Expander
  • Interchangeable Covers

edwards edwards SIGA-PHD-SIGA-PHDB-Intelligent
0 out of 5

• Next Generation Detection Technology
• Integrates optical smoke with rate-of-rise heat sensing
• Wide 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) smoke obscuration
• Uses existing wiring
• Automatic device mapping
• Sensor Markings Provide Easy Testing Identification
• Up To 250 Total Signature Addresses Per Loop
• Two levels of environmental compensation
• Two levels of dirty detector warning
• Twenty pre-alarm settings
• Five sensitivity settings
• Non-volatile memory
• Electronic addressing
• Environmental compensation

• Automatic day/night sensitivity adjustment
• Bicolor (green/red) status LED
• Standard, relay, fault isolator, and audible mounting bases

 

Related Products:

  • SPECIFY A SIGNATURE SOLUTION                          Signature Optica™ Smoke Detectors
  • Signature Optica™ Smoke and Heat Detectors          Signature Optica™ Smoke, Heat, and Carbon Monoxide Detectors
  • Signature Intelligent Multisensor Detectors               Signature Optica™ Smoke and Carbon Monoxide Detectors
  • Intelligent Input & Output Modules                             Pull Stations
  • Specialized                                                                          Signature Optica™ Multisensor Detectors
  • Signature Optica™ Senior Living                                  Signature Optica™ Overview
  • INTELLIGENT SOLUTIONS                                         CONVENTIONAL SOLUTIONS
  • ASPIRATING DETECTION                                            Signature Optica™ Overview
  • Signature Optica™ Multisensor Detectors                  Signature Optica™ Steam Test
  • SPEAKER-STROBE APPLIANCES                               HORN-STROBE APPLIANCES
  • VOICE COMMUNICATIONS SYSTEMS                     Genesis™ LED Notification Appliances.
  • Mass Notification System Planning                              Universal Room-Side Wiring Plate
  • G4SE Strobe Expander                                                    Interchangeable Covers

cooper Efxn 533
0 out of 5

JSB Optical Smoke Detector
A comprehensive range of conventional detectors are available for the JSB EFX2200 range of fire detection panels.
Features:
* LPCB 3rd party approved
* Low profile design
* 360° viewable LED design
* Removable detector chamber for cleaning
* Common mounting base
* New enhanced detectors feature Drift compensation and Chamber monitoring (FXN533 & FXN632)

Fire alarm Esser detector IQ8Quad 802382
0 out of 5

  • The reliable sensor principle for consistent

response performance at the highest level of

security against false alarms

  • Loop powered – no need for external power supply
    • Individual control of the sounder
    • Tones can be used for other purposes in addition to
    warning of fire, making the device ideal for use in
    schools (school bell) etc.
    • Soft start option, ideal for hospitals and nursing homes
    • No additional short address
    • Automatic synchronization of various IQ8Quad alarm signaling devices
    • Maximum sound level: 92 dB (A) at 1 m
    • Maximum sound pressure can be set
    • Multiple signal components can be combined to one signal template
    • Signal template and repetition rates can be set
    • Up to 26 different languages are available
    • 20 different signal tones, incl. DIN-tone
    • Low power consumption

edwards eswards EST-iO1000
0 out of 5

• Comes standard with one loop (expandable to two) that
supports up to 250 (expandable to 500) intelligent devices:
each iO500 loop supports up to 125 detectors and up to 125
modules.
• Supports Signature Series intelligent modules and detectors
• Combines the Signature intelligent releasing module with
Signature multisensor detectors for reliable suppression
• Four Class B NACs or two Class A NACs.
• Form C contacts for alarm and trouble, Form A for supervisory
• Electronic addressing with automatic device mapping
• Optional Ethernet port for diagnostics, programming and a
variety of system reports
• Two programmable switches with LEDs and custom labeling
• Supports Genesis horn silence over two wires and UL
1971-compliant strobe synchronization
• Supports up to eight serial annunciators, (LCD, LED-only, and
graphic interface).
• 1,000 event panel history log
• Can use existing wiring for most retrofit applications
• Upload/download remotely or locally
• Two-level maintenance alert reporting
• Pre-alarm and alarm verification by point
• Adjustable detector sensitivity
• 4 x 20 character backlit LCD display
• Optional earthquake hardening: OSHPD seismic pre-approval
for component Importance Factor 1.5

 

 Related Products:

  • MANAGEMENT IS A MUST                                    FW-FAST
  • FW-HSSX1: Aspirated Detection Interface           FW-DARCOM: Third-party Interoperability
  • FW-IPMON1000: Life Safety Integration             WebClients: Global VPN Communications
  • Workstations                                                                Servers
  • Monitors                                                                       EST4 Fire & Life Safety Platform
  • iO Life Safety System                                                 Fire Safety System Upgrades
  • EMPOWERING PROACTIVE SERVICE               Meet the ESTMobile™ App
  • George McNeill & His ESTMobile™ Experience

cooper FL-RL-R-D
0 out of 5

Cooper Menvier FL-RL-R-D Conventional Xenon Sounder Beacon (Deep Base)
The Xenon is an audible and visual device which requires one single installation point. This greatly reduces installation costs and is less obtrusive than two separate devices. Versions are available with the sounder and beacon linked, or with separate terminals for independent operation