eatures
• 4 Fixed Zones
• Supports up to 128 detectors
• Unlimited call points
• 1 “fire” and 1 “fault” relay outputs
• 2 monitored sounder outputs
• Active EOL allowing continuous monitoring of inputs
• Walk test
• LED indication
• Levels of access protected by means of security key
• Plastic box
• Audio and visual alerts
• Floor plan system visualisation
• 3D idle/overview mode including mouse hover/click interaction
• Sweeping animations
• Programmable buttons and displays
• Quick and intuitive to set up and use
• Remote and multi-user access with defined credentials
• Password and pin code protection
• Network history view/search
• Printable reports
• Multi network supervision over TCP/IP
> High output sounder beacon
> Sounder and beacon with a single installation point
> Unobtrusive low profile design
> Volume contol
> Lockable base
• Flexible, high specification system
• Very easy to maintain and service
• Suitable for a large range of projects
• No fuses required
• Maintenance free poly switch circuit protection, with
auto reset
• Class change and programmable fire/fault relay as
standard on 2/4 zone and fire and fault on the 8 zone
• Discreet panel design
• Numerical access code (no lost keys)
• The 8 zone variant features configurable zonal relay
card option and interlink
• Supplied complete with battery for 24 hour standby
Related Products:
- Optical smoke beam detector for conventional fire systems
- Remote indicator for conventional fire systems
- Sounder detector base for conventional fire systems
- Ultra-low current sounder for conventional fire systems
- UL optical, photo thermal & heat conventional detector range
- Sounder visual alarm device for conventional fire systems
The Wheelock® ExcederTM Series incorporates high reliability and
high efficiency optics to minimize current draw allowing for a greater
number of appliances on the notification appliance circuit. All strobe
models feature an industry first of 8 candela settings on a single
appliance. Models with an audible feature 3 sound settings (90, 95,
99 dB). All switches to change settings, can be set without the use
of a tool and are located behind the appliance to prevent tampering.
Wall models feature voltage test points to take readings with a
voltage meter for troubleshooting and AHJ inspection.
Related Products:
- Optical smoke beam detector for conventional fire systems
- Remote indicator for conventional fire systems
- Sounder detector base for conventional fire systems
- Ultra-low current sounder for conventional fire systems
- UL optical, photo thermal & heat conventional detector range
- Sounder visual alarm device for conventional fire systems
• Soft addressed
• Integral short circuit isolator
• Single address
• Non latching changeover
relay contacts
• Suitable for switching low
volts control gear
• Optional variant:
Related Products:
- Visual alarm device for conventional fire systems
- Wheelock Exceder horn strobes
- Wheelock Exceder horns
- Xenon sounder beacon for conventional fire systems
- Wheelock RSS strobes
- Wheelock Exceder strobes
• Fully passive
• Up to 200 Repeaters can be
connected to the loop
• Surface or semi-recessed
mounting
• 2 x 40 backlit LCD display and
6 supervisory LED’s
• Compact size
Related Products:
- ULFX6000
- ULFX6000RM
- ULMIU872
- ULMCIM
- ULMCIM-C
- ULMCOM
- ULMCOM-S
• Approvals include: UL Standard 1971, UL Standard 1480, New York
City (MEA), California State Fire Marshall (CSFM), Factory Mutual
(FM), and Chicago (BFP) See approvals by model in Specifications
and Ordering Information
• ADA/NFPA/UFC/ANSI compliant
• Meets OSHA 29 Part 1910.165
• Wall mount models are available with Field Selectable Candela
Settings of 15/30/75/110cd or 135/185cd (Multi-Candela models) or
1575cd (Single Candela model)
• Ceiling mount models are available with field selectable candela
settings of 15/30/75/95cd or 115/177cd (multi-candela models)
• Strobes produce 1 flash per second over the regulated voltage range
• 24 VDC with wide UL “Regulated Voltage” using filtered DC or
unfiltered VRMS input voltage
• Synchronize with sync modules or panels with built-in Wheelock
Patented Sync Protocol
• Field selectable taps for 25 or 70 VRMS operation from 1/8 watt
to 8 watts
• High efficiency design for maximum output at minimum wattage
across a frequency range of 400 to 4000 HZ
• Fast installation with IN/OUT screw terminals using #12 to #18
AWG wires
Related Products:
- Sounder detector base for conventional fire systems
- Visual alarm device for conventional fire systems
- UL optical, photo-thermal & heat addressable detector range
- UL optical, photo thermal & heat conventional detector range
- Wheelock Exceder horns
• Soft addressed
• Integral short circuit isolator
• Single address
• Suitable for monitoring:
– Flow switches
– Non fire inputs
– Auxillary panels
• Optional variant:
– ULMCIM-C
Related Products:
- Compact wall sounder for conventional fire systems
- Loop splitter for addressable fire alarm systems
- Loop mimic PCB for addressable fire systems
- Loop design calculator software for fire systems
- Loop tester kit for addressable fire systems
The Fgard IR3 delivers superior performance in the detection of hydrocarbon fires, using the latest infrared (IR) flame detection algorithms to minimise the risk of false alarms.
The Fgard IR3 has been independently tested to demonstrate it can detect a hydrocarbon fuel pan fire at nearly 200 feet in less than 5 seconds, maximising the time you have to respond in an emergency.
Its multi-spectrum IR will detect all hydrocarbon fires with intelligent heated optics, meaning no condensation, ice or water affecting detection. Plus, its advanced optical verification checks cleanliness of the lens and electronic circuitry, meaning no reflector optical check is needed, and a large optical surface results in far fewer false alarms.
Applications
Typical applications include:
� On / Offshore Oil and Gas
Processing Facilities
� Refineries
� Petrochemical Plants
� Chemical Facilities
� Pharmaceutical
� Aircraft Hangars
� Road Tunnels
� Power Generation
� Tank Farms
� Road & Rail Loading Racks
� LNG / LPG
� Warehouses / Storage Areas
� Waste Recycling / Biomass Plants
� Printing Industry
Features and benefits
� Multi Spectrum IR design delivers long detection
distances and enhanced false alarm immunity
� Continuous optical test, without a reflector
•Verifies operation and improves device up-time
� Microprocessor controlled heated optics
•Maintains operation in harsh weather
conditions (snow, ice, condensation)
� International hazardous area approvals
•FM / ATEX / IEC Ex / INMETRO / PESO
� Certified performance testing to multiple fuels
•FM 3260
•EN 54-10
� Adjustable sensitivity levels
•For application flexibility
•Ensure detectors do not cross vote
� External testing with a long-range flame simulator
•Minimises the need for scaffolding
� Easy integration using industry
standard outputs:
•Alarm and Fault Relays
•4-20mA
•HART®, as standard
� Certified SIL 2 Capable
•5-year warranty
The Dalton B33 Series UPS offers reliable power protection with advanced digital signal processing (DSP) control and online double conversion technology, classified under VFI-SS-111 according to IEC EN 62040-3. This series is designed with a green manufacturing philosophy, aiming for a reduced environmental impact through minimized space usage, fewer components, and controlled noise pollution.
Key Features
Power Range: 10 – 120 kVA
Input & Output: Three-phase
Technology: Online double conversion
Environmental Impact: Reduced carbon footprint with a focus on minimal space, fewer components, and lower noise levels
Advanced Communications
Remote Monitoring: Compatible with TeleNetGuard for remote monitoring
Software Compatibility:
PowerShield3 Monitoring and Shutdown Software: Included for various operating systems
Supported Systems: Windows (10, 8, 7, Hyper-V, 2016, 2012, and previous versions), Mac OS X, Linux, VMWare ESXi, Citrix XenServer, and other Unix operating systems
The Dalton R10 Series is a rack-mounted UPS designed for critical load protection, including IT equipment, data centers, and servers. It features advanced DSP true online double conversion technology to safeguard valuable equipment and critical data from power interruptions such as surges, blackouts, and lightning strikes.
Key Features
Type: Rack-mounted
Technology: True online double conversion with DSP (Digital Signal Processor)
Applications: Ideal for protecting IT infrastructure, data centers, servers, and other critical equipment
Protection: Guards against power interruptions including surge
General Details
The Dalton U10 Series UPS provides a single-phase pure sine wave power supply with capacities ranging from 1 kVA to 10 kVA. Incorporating double-converter technology, this UPS ensures high-quality power with exceptional availability and reliability. It is designed to be compact and user-friendly, making it suitable for a variety of essential applications.
Key Features
Type: Single-phase pure sine wave UPS
Capacity: 1 kVA – 10 kVA
Technology: Double-converter technology
Input & Output: Single-phase
Applications: Ideal for critical equipment in sectors such as finance, communication, government, traffic, manufacturing, education