Showing 16–30 of 54 results

cooper cooper ULFX6000 & ULFX6000RM
0 out of 5

• Approvals include: UL Standard 1971, UL Standard 1480, New York
City (MEA), California State Fire Marshall (CSFM), Factory Mutual
(FM), and Chicago (BFP) See approvals by model in Specifications
and Ordering Information
• ADA/NFPA/UFC/ANSI compliant
• Meets OSHA 29 Part 1910.165
• Wall mount models are available with Field Selectable Candela
Settings of 15/30/75/110cd or 135/185cd (Multi-Candela models) or
1575cd (Single Candela model)
• Ceiling mount models are available with field selectable candela
settings of 15/30/75/95cd or 115/177cd (multi-candela models)
• Strobes produce 1 flash per second over the regulated voltage range
• 24 VDC with wide UL “Regulated Voltage” using filtered DC or
unfiltered VRMS input voltage
• Synchronize with sync modules or panels with built-in Wheelock
Patented Sync Protocol
• Field selectable taps for 25 or 70 VRMS operation from 1/8 watt
to 8 watts
• High efficiency design for maximum output at minimum wattage
across a frequency range of 400 to 4000 HZ
• Fast installation with IN/OUT screw terminals using #12 to #18
AWG wires

 

 Related Products:

  • Sounder detector base for conventional fire systems
  • Visual alarm device for conventional fire systems
  • UL optical, photo-thermal & heat addressable detector range
  • UL optical, photo thermal & heat conventional detector range
  • Wheelock Exceder horns

cooper cooper ULMCIM
0 out of 5

• Soft addressed
• Integral short circuit isolator
• Single address
• Suitable for monitoring:
– Flow switches
– Non fire inputs
– Auxillary panels
• Optional variant:
– ULMCIM-C

 

Related Products:

  • Compact wall sounder for conventional fire systems
  • Loop splitter for addressable fire alarm systems
  • Loop mimic PCB for addressable fire systems
  • Loop design calculator software for fire systems
  • Loop tester kit for addressable fire systems

Fire alarm Crowcon Fgard IR3 flame detector
0 out of 5

The Fgard IR3 delivers superior performance in the detection of hydrocarbon fires, using the latest infrared (IR) flame detection algorithms to minimise the risk of false alarms.
The Fgard IR3 has been independently tested to demonstrate it can detect a hydrocarbon fuel pan fire at nearly 200 feet in less than 5 seconds, maximising the time you have to respond in an emergency.
Its multi-spectrum IR will detect all hydrocarbon fires with intelligent heated optics, meaning no condensation, ice or water affecting detection. Plus, its advanced optical verification checks cleanliness of the lens and electronic circuitry, meaning no reflector optical check is needed, and a large optical surface results in far fewer false alarms.
Applications
Typical applications include:
� On / Offshore Oil and Gas
Processing Facilities
� Refineries
� Petrochemical Plants
� Chemical Facilities
� Pharmaceutical
� Aircraft Hangars
� Road Tunnels
� Power Generation
� Tank Farms
� Road & Rail Loading Racks
� LNG / LPG
� Warehouses / Storage Areas
� Waste Recycling / Biomass Plants
� Printing Industry
Features and benefits
� Multi Spectrum IR design delivers long detection
distances and enhanced false alarm immunity
� Continuous optical test, without a reflector
•Verifies operation and improves device up-time
� Microprocessor controlled heated optics
•Maintains operation in harsh weather
conditions (snow, ice, condensation)
� International hazardous area approvals
•FM / ATEX / IEC Ex / INMETRO / PESO
� Certified performance testing to multiple fuels
•FM 3260
•EN 54-10
� Adjustable sensitivity levels
•For application flexibility
•Ensure detectors do not cross vote
� External testing with a long-range flame simulator
•Minimises the need for scaffolding
� Easy integration using industry
standard outputs:
•Alarm and Fault Relays
•4-20mA
•HART®, as standard
� Certified SIL 2 Capable
•5-year warranty

edwards edwards est4
0 out of 5

• Investment-forward Platform Designed for the Future
Protects the past with backwards compatibility
for EST3 retrofits, flexible feature set.
• On-board Webserver
Remote device-independent access to system status reports.
• Built-in E-mail and E-mail-to-SMS Messaging
Instant notification of specific event types
sent to appropriate personnel.
• Large Full-color LCD Touch Screen with Tactile Buttons
Fast, intuitive access to service and responder functions.
• Five-color LED Indicators
System status at a glance, select the color needed
during programming, reduces replacement part
inventory, maximizes use of available infrastructure.
• Network data, audio data, and telephone
data share a single twisted pair or single fiber strand
Up to 75 percent less cabling, substantial
cost savings in material and labor.
• Backwards Compatibility with EST3
Wiring, devices, and most local rail modules are
backward compatible, providing easy migration
paths, economical transition to new technology.
• Existing Systems Supporting only
Network Data can also Support Voice Audio
Upgrades add value and extend capabilities in retrofit situations.

 

  Related Products:

  • EST3                                                                               EST3X
  • iO SERIES                                                                     Amplifiers
  • Annunciators (R-Series)                                            Batteries and Power Supplies
  • Pull Stations                                                                 Beam & Duct Detectors
  • SCALABLE ASPIRATING DETECTION                ModuLaser® Aspirating Smoke Detection System
  • VESDA by Xtralis®                                                    ModuLaser® Aspirating Smoke Detection
  • ModuLaser® Aspirating Detection                        CONFIGURATION IS KEY
  • Genesis LED Series                                                    Genesis Outdoor Series
  • Universal Room-Side Wiring Plate                        G4SE Strobe Expander
  • Interchangeable Covers

edwards edwards SIGA-PHD-SIGA-PHDB-Intelligent
0 out of 5

• Next Generation Detection Technology
• Integrates optical smoke with rate-of-rise heat sensing
• Wide 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) smoke obscuration
• Uses existing wiring
• Automatic device mapping
• Sensor Markings Provide Easy Testing Identification
• Up To 250 Total Signature Addresses Per Loop
• Two levels of environmental compensation
• Two levels of dirty detector warning
• Twenty pre-alarm settings
• Five sensitivity settings
• Non-volatile memory
• Electronic addressing
• Environmental compensation

• Automatic day/night sensitivity adjustment
• Bicolor (green/red) status LED
• Standard, relay, fault isolator, and audible mounting bases

 

Related Products:

  • SPECIFY A SIGNATURE SOLUTION                          Signature Optica™ Smoke Detectors
  • Signature Optica™ Smoke and Heat Detectors          Signature Optica™ Smoke, Heat, and Carbon Monoxide Detectors
  • Signature Intelligent Multisensor Detectors               Signature Optica™ Smoke and Carbon Monoxide Detectors
  • Intelligent Input & Output Modules                             Pull Stations
  • Specialized                                                                          Signature Optica™ Multisensor Detectors
  • Signature Optica™ Senior Living                                  Signature Optica™ Overview
  • INTELLIGENT SOLUTIONS                                         CONVENTIONAL SOLUTIONS
  • ASPIRATING DETECTION                                            Signature Optica™ Overview
  • Signature Optica™ Multisensor Detectors                  Signature Optica™ Steam Test
  • SPEAKER-STROBE APPLIANCES                               HORN-STROBE APPLIANCES
  • VOICE COMMUNICATIONS SYSTEMS                     Genesis™ LED Notification Appliances.
  • Mass Notification System Planning                              Universal Room-Side Wiring Plate
  • G4SE Strobe Expander                                                    Interchangeable Covers

Fire alarm Esser detector IQ8Quad 802382
0 out of 5

  • The reliable sensor principle for consistent

response performance at the highest level of

security against false alarms

  • Loop powered – no need for external power supply
    • Individual control of the sounder
    • Tones can be used for other purposes in addition to
    warning of fire, making the device ideal for use in
    schools (school bell) etc.
    • Soft start option, ideal for hospitals and nursing homes
    • No additional short address
    • Automatic synchronization of various IQ8Quad alarm signaling devices
    • Maximum sound level: 92 dB (A) at 1 m
    • Maximum sound pressure can be set
    • Multiple signal components can be combined to one signal template
    • Signal template and repetition rates can be set
    • Up to 26 different languages are available
    • 20 different signal tones, incl. DIN-tone
    • Low power consumption

edwards eswards EST-iO1000
0 out of 5

• Comes standard with one loop (expandable to two) that
supports up to 250 (expandable to 500) intelligent devices:
each iO500 loop supports up to 125 detectors and up to 125
modules.
• Supports Signature Series intelligent modules and detectors
• Combines the Signature intelligent releasing module with
Signature multisensor detectors for reliable suppression
• Four Class B NACs or two Class A NACs.
• Form C contacts for alarm and trouble, Form A for supervisory
• Electronic addressing with automatic device mapping
• Optional Ethernet port for diagnostics, programming and a
variety of system reports
• Two programmable switches with LEDs and custom labeling
• Supports Genesis horn silence over two wires and UL
1971-compliant strobe synchronization
• Supports up to eight serial annunciators, (LCD, LED-only, and
graphic interface).
• 1,000 event panel history log
• Can use existing wiring for most retrofit applications
• Upload/download remotely or locally
• Two-level maintenance alert reporting
• Pre-alarm and alarm verification by point
• Adjustable detector sensitivity
• 4 x 20 character backlit LCD display
• Optional earthquake hardening: OSHPD seismic pre-approval
for component Importance Factor 1.5

 

 Related Products:

  • MANAGEMENT IS A MUST                                    FW-FAST
  • FW-HSSX1: Aspirated Detection Interface           FW-DARCOM: Third-party Interoperability
  • FW-IPMON1000: Life Safety Integration             WebClients: Global VPN Communications
  • Workstations                                                                Servers
  • Monitors                                                                       EST4 Fire & Life Safety Platform
  • iO Life Safety System                                                 Fire Safety System Upgrades
  • EMPOWERING PROACTIVE SERVICE               Meet the ESTMobile™ App
  • George McNeill & His ESTMobile™ Experience

Fire alarm FSL 100-IR3 honeywell flame detector
0 out of 5

The Honeywell FSL100 Series Flame Detectors are Optoelectronic flame detectors for a wide range of Light Industrial fire detection from Honeywell Analytics.

Honeywell’s FSL100 range of Light Industrial/Commercial Flame Detectors enables simple coverage of fire hazard areas across many fire hazard applications. Installation, set-up and operation are simple. Wide solid area coverage and fast speed of response optimise safety. With inbuilt automatic test and test lamps available to cover all models, reliability is ensured.

A range of middle-market Optical Flame Detectors join the HA FSX High-End products. Addresses a wide range of fire protection applications both indoors and outdoors. With 3 versions to cover a wide range of flaming fires: Ultraviolet (UV), Ultraviolet/Infrared (UV/IR) and Triple Infrared (IR3).

Detecting a wide range of Hydrocarbon and Non-Hydrocarbon flaming fires means that many application areas can be addressed. Wide viewing angleOptical detection of radiant energy in a solid angle Field of View enables coverage of a large risk area. A simple optional mounting bracket allows the FSL100 to be installed and aligned covering the hazard. Fast responseFar faster than other technologies, by responding to flaming fires in seconds enabling a more rapid response to danger before the fire can escalate.

FM Class 1, 2 & 3 Div2 can be installed indoors or outdoors and in Hazardous areas typically looking into a Div 1 area from a distance. FM 3260 performance certified to FM 3260 for flame Detector performance. Relay and current output (Fault and Alarm) Analog stepped output and Alarm/Fault relays for simple connectivity. Inbuilt Automatic Test and Simple to use Test LampsFSL100 maintains continuous internal health monitoring. Test lamps enable simple operational and field-of-view testing.

Fire alarm Gent Beam detector S4-34740
0 out of 5

Gent S4-34740 Beam Sensor Pair (Transmitter and Receiver) Excluding Bracket and Base

Gent S4-34740 S-Quad Addressable Loop Powered Beam Sensor Pair provides an enhanced solution for linear beam detection for applications where Gent S4 Vigilon point detection is either not practical or economic.

Powered and controlled via the loop, the beam is a market leading device with features such as one man alignment and commissioning which is achieved using the auto gain setting, this ensure the optimum alignment is reached.

Maintenance of the beam is enhanced with a key operated test feature which simulates the obscuration of the beam in a fire.

The Gent loop powered beam is certified to EN54 parts 12 and 17. Compatible with the full range of Vigilon and Nano control panels the S-Quad beam uses the panel software to ensure a fast response to fire while offering software filters to reduce the number of unwanted alarms.

Fire alarm Gent COMPACT-NC Compac
0 out of 5

The COMPACT-NC is a Compact Network Card for Vigilon Compact Control Panels.
This copper network card is used to allow data to pass between control panels in a Vigilon Compact networked fire system. The card must be plugged into the Master Control board MCB of the panel in a dedicated slot ‘CARD 2’. The card has terminals to accept external network wiring. A bank of dual-in-line switches on the card allow setting of address number and baud rate.
Key Features
* Links together 2 or more Vigilon Compact or Vigilon Compact Plus fire alarm panels.
* Expands the Vigilon compact panel

Fire alarm Gent COMPACT-PLUS
0 out of 5

Gent COMPACT-PLUS Vigilon Compact Plus 1-2 Loop Control Panel with 1 Loop Card
Vigilon Plus Control Panels are available in 3 sizes managing 2, 4 or 6 loops each accommodating up to 200 devices including advanced fire sensors, interfaces, call points, alarm sounders and visual alarms. The Compact Plus 2 loop panels and Vigilon Plus 4 loop panels are available with integrated 24 hour standby and the 6-loop panel has full 72 hr standby capacity

Fire alarm Gent S3-s-VAD-HPR-R
0 out of 5

The Gent S-Cubed offers a comprehensive range of loop powered alarm sounders with integrated voice and visual alarms. The sounders shall be capable of providing 3 different sound signals, which are selected/configured via the main control panel. Configuration of sounder patterns will not be carried out locally at individual sounders. In order to meet with the requirements of BS5839 Part 1, the frequency of sound signals emitted will be as follows:
Features & Benefits:
* 200 per loop
* Red & White options
* 103dbA at 1 metre
* 3 Sound signals
* 2 integral Line Isolators

Fire alarm honeywell Gent Gent S4-710
0 out of 5

The S4-710 is specifically designed to be used with the Gent Vigilon range of Analogue Addressable Control Panels. This detector is an Optical Type Analogue Addressable Smoke Detector combined with a Heat Detection Element. It requires a Gent S4-700 base for mounting.
The S4-710 is a truly intelligent analogue sensor combining local processing in the sensor and the panel to achieve an immediate response to real fires whilst minimising the risk of false alarms.

Fire alarm honeywell Gent S4-34845
0 out of 5

S4-34845 Manual Call Point with Protective Cover & Resettable Element
The S4-34845 is a Addressable Manual Call Point (MCP) from the Gent range. The S4-34845 has an response time of less than 1 second. The S4-34845 Manual Call Point comes with a protective cover and also comes with the resettable element, which can be done at any given time using a Call Point Test Key seen in the related products.
The Addressable Range of Gent Manual Call Points (MCP) are for the Vigilon and Nano System, which are easy to install and have the ability to be mounted on standard installation back boxes or they can be mounted on bespoke red back boxes for surface mounting.

Fire alarm Honeywell 6815
0 out of 5

silent knight 6815 alarm:

The 6815 is a signaling line circuit (SLC) expander for use with Honeywell
Silent Knight 6820 or 6820EVS fire alarm control panels (FACPs)using
System Sensor® (SK) protocol. The 6815 signaling circuit has the same
functionality as the SLC that is built into the 6820 and 6820EVS panels
and support the same addressable devices as the one in each panel. The
number of 6815 SLCs that can be used within one system is largely
dependent on maximum available points. They provide a powerful way to
customize configurations in large or complex installs.

FEATURES
• The number of 6815 SLCs that can be used in one system is
largely determined by maximum point counts. With 1,110
available points on the 6820 and 6820EVS and 6815 SLC
flexibility, new design and installation opportunities are now possible.
• Use the 5815RMK mounting kit to securely house more SLCs within one system.
• Pair with the separate 6860 remote annunciator for additional installation
and operating options. The 6860 has four programmable
buttons that are useful for executing routine or complex tasks.
• Up to two additional 6815 SLCs can be
securely housed in one FACP, thus limiting the need for separate housing
• Useful for installations where buildings are connected for
multi-site benefits using fiber optic or copper wiring. The ability to use multiple
6815 SLCs in these situations provides additional fire system design options.