Fire alarm Gent Beam detector S4-34740
0 out of 5

Gent S4-34740 Beam Sensor Pair (Transmitter and Receiver) Excluding Bracket and Base

Gent S4-34740 S-Quad Addressable Loop Powered Beam Sensor Pair provides an enhanced solution for linear beam detection for applications where Gent S4 Vigilon point detection is either not practical or economic.

Powered and controlled via the loop, the beam is a market leading device with features such as one man alignment and commissioning which is achieved using the auto gain setting, this ensure the optimum alignment is reached.

Maintenance of the beam is enhanced with a key operated test feature which simulates the obscuration of the beam in a fire.

The Gent loop powered beam is certified to EN54 parts 12 and 17. Compatible with the full range of Vigilon and Nano control panels the S-Quad beam uses the panel software to ensure a fast response to fire while offering software filters to reduce the number of unwanted alarms.

Fire alarm Gent COMPACT-NC Compac
0 out of 5

The COMPACT-NC is a Compact Network Card for Vigilon Compact Control Panels.
This copper network card is used to allow data to pass between control panels in a Vigilon Compact networked fire system. The card must be plugged into the Master Control board MCB of the panel in a dedicated slot ‘CARD 2’. The card has terminals to accept external network wiring. A bank of dual-in-line switches on the card allow setting of address number and baud rate.
Key Features
* Links together 2 or more Vigilon Compact or Vigilon Compact Plus fire alarm panels.
* Expands the Vigilon compact panel

Fire alarm Gent COMPACT-PLUS
0 out of 5

Gent COMPACT-PLUS Vigilon Compact Plus 1-2 Loop Control Panel with 1 Loop Card
Vigilon Plus Control Panels are available in 3 sizes managing 2, 4 or 6 loops each accommodating up to 200 devices including advanced fire sensors, interfaces, call points, alarm sounders and visual alarms. The Compact Plus 2 loop panels and Vigilon Plus 4 loop panels are available with integrated 24 hour standby and the 6-loop panel has full 72 hr standby capacity

Fire alarm Gent S3-S-R S3
0 out of 5

Gent S3-S-R S3 Sounder with Red Body
* S-Cubed offers a comprehensive range of loop powered alarm sounders with integrated voice and EN54-23 certified visual alarms. Combined with flexible configuration from the Gent by Honeywell fire control panels, this loop powered device can give a differentiated combination of audible and visual alarms for alert and general evacuation.

Fire alarm Gent S3-s-VAD-HPR-R
0 out of 5

The Gent S-Cubed offers a comprehensive range of loop powered alarm sounders with integrated voice and visual alarms. The sounders shall be capable of providing 3 different sound signals, which are selected/configured via the main control panel. Configuration of sounder patterns will not be carried out locally at individual sounders. In order to meet with the requirements of BS5839 Part 1, the frequency of sound signals emitted will be as follows:
Features & Benefits:
* 200 per loop
* Red & White options
* 103dbA at 1 metre
* 3 Sound signals
* 2 integral Line Isolators

Fire alarm honeywell Gent Gent S4-710
0 out of 5

The S4-710 is specifically designed to be used with the Gent Vigilon range of Analogue Addressable Control Panels. This detector is an Optical Type Analogue Addressable Smoke Detector combined with a Heat Detection Element. It requires a Gent S4-700 base for mounting.
The S4-710 is a truly intelligent analogue sensor combining local processing in the sensor and the panel to achieve an immediate response to real fires whilst minimising the risk of false alarms.

Fire alarm honeywell Gent S4-34845
0 out of 5

S4-34845 Manual Call Point with Protective Cover & Resettable Element
The S4-34845 is a Addressable Manual Call Point (MCP) from the Gent range. The S4-34845 has an response time of less than 1 second. The S4-34845 Manual Call Point comes with a protective cover and also comes with the resettable element, which can be done at any given time using a Call Point Test Key seen in the related products.
The Addressable Range of Gent Manual Call Points (MCP) are for the Vigilon and Nano System, which are easy to install and have the ability to be mounted on standard installation back boxes or they can be mounted on bespoke red back boxes for surface mounting.

Fire alarm honeywell gent S-Quad Sensor
0 out of 5

• Complete range of sensors with
combinations of advanced sensing
technologies including heat, dual angle
optical scatter and carbon monoxide (CO)
• Combined sensing of carbon monoxide with dual angle optical scatter and heat
allows a higher level of false alarm immunity in presence of steam
and while still maintaining the integrity of detecting fi res
• Each sensor has certifi ed sensitivity settings that suit
certain environments/ applications and may
be programmed for different times of the day if required
• Short circuit Isolator in each device
• Confi gurable input/ output connection for remote indicator or
supervisory input fully synchronised sound
patterns via the control panel
• Sensor sounders have adjustable sound level
and tones to match system sounders
• Sounder element monitoring and over-load protection
to ensure operation even in event of cable fault
• Sound output synchronised and compatible with
S-Quad range of EN54-23 VADs.

 

  Related Products:

  • S-Quad Multi-Sensor with                       Integrated Sounder and Visual
  • Alarms Device (VAD)                               S-Cubed
  • Analogue Addressable Manual               Call Points
  • Beam Sensors                                             SAFE Solution
  • Loop Powered Interfaces                         Mains Switching Interface
  • Mains Powered Interface                         34000 S-Quad Adapter Base.
  • S-Quad Anti-Ligature Base                      EN54-4 Approved Power Supply Units
  • Electromagnetic Door Holders               Transformer Rectifier 24v Door Retainer
  • Fire System Document Box                     PAGING
  • RESPONSE AID                                        PAGING
  • RESPONSE PLUS                                     Response Plus
  • RECHARGEABLE TFT                            DISPLAY PAGER
  • PAGING

Fire alarm honeywell gent S4-34420 module
0 out of 5

Gent S4-34420 Interface Single Channel Low Voltage Output (PCB and Enclosure Seperate, Housing Required)
Vigilon can accommodate a high quantity of loop powered interface units offering flexible range of inputs and outputs from the FD&A system from plant control and signalling other systems in a fi re, to linking with other emergency management systems such as sprinklers or security systems.
Loop powered interfaces offer a cost-effective solution with each device individually addressed increasing the overall management capability of the FD&A system.
Interfaces are either powered from the loop or require a separate mains supply. The mains power version has its own battery backup.

Fire alarm honeywell gent Vigilon Plus Control Panel
0 out of 5

• Integral EN54-4 PSUand battery standby for 24 hours (4 loop)
• Integral EN54-4 PSU for 72 hours with external batteries (6 loop)
• Vigilon’s advanced sensing technology and powerful software
processing in the panel quickly identifies real fires
• PC based commissioning tools
allow complex fire plans to be configured
• Advanced loop card technology allows for
system status monitoring and diagnostics
• Extended event log using flash memory card
• The control panel has a simple user interface
with LCD screen providing accurate information in an emergency
• Multiple panel networks can be programmed
seamlessly as one system, allowing for
flexible design and system management
• Flexible programming options are available at the panel
• All Vigilon devices connect onto the same
two core loop, separate sounder or
repeater panel wiring circuits are not required
• In the event of a fire or fault, Vigilon’s analogue addressable
technology will provide a detailed log of events
• PC based Graphics user interface (GUI) available

 

  Related Products:

  • BACnet Gateway                                Single Mode FibreVisual Alarm Devices
  • Advanced Vigilon Loop Card          Nano Control Panel
  • Vigilon Plus Control Panels            Non-Addressable Audible
  • Visual Devices                                    Electronic Bells
  • Xenex Control Panel                        Conventional Manual Call Points
  • ES Detect                                            Non-Addressable Audible
  • Visual Alarm Devices                       Non-Addressable Audible
  • Visual Alarm Devices                       FAAST
  • AUTOMATIC                                     PURGING UNIT
  • SAMPLING HOLE                            IDENTIFICATION
  • VESDA